RE: [PSUBS-MAILIST] Interphase Vista



Jon,
 
  One fine point to mention...the "shields" you refer to are but a very thin films or sheets of aluminum. These are not terminated to any point but do contact the aluminum covering the other wires...at some point these "shields" contact the bare wire and channel any emi to ground via this bare wire.
 
  These "shields" will not be able to be passed thru any connection point as these are not braded wire as is sometimes the case. It would have been easier had each shield been made from braded wire, but then we would not been working on this problem.
 
                                                                                                                                                 David Bartsch
 
> Date: Thu, 18 Mar 2010 14:08:50 -0400
> From: jonw@psubs.org
> To: personal_submersibles@psubs.org
> Subject: Re: [PSUBS-MAILIST] Interphase Vista
>
>
> David,
>
> I've got the concept now so you don't need to take it apart again for
> photos.
>
> Subconn makes a 16 pin connector. This would allow a separate pin for
> each of the 8 insulated wires, plus each associated shield. Since the
> ninth wire is meant to contact the shields, it sounds like it could be
> passed through the same pin as any one of the shields.
>
> Jon
>
>
>
>
> ************************************************************************
> ************************************************************************
> ************************************************************************
> The personal submersibles mailing list complies with the US Federal
> CAN-SPAM Act of 2003. Your email address appears in our database
> because either you, or someone you know, requested you receive messages
> from our organization.
>
> If you want to be removed from this mailing list simply click on the
> link below or send a blank email message to:
> removeme-personal_submersibles@psubs.org
>
> Removal of your email address from this mailing list occurs by an
> automated process and should be complete within five minutes of
> our server receiving your request.
>
> PSUBS.ORG
> PO Box 53
> Weare, NH 03281
> 603-529-1100
> ************************************************************************
> ************************************************************************
> ************************************************************************
>


Hotmail is redefining busy with tools for the New Busy. Get more from your inbox. Sign up now.