Hugh,

Do you have another reference for the 3/8 inch minimum bolt size? I found a reference in Section 7.1.3 that points to ASME PVHO-1, but nothing else. I don't have access to PVHO-1.

Jon


Hugh Fulton wrote:
Jon, I tend to agree but have also requested an answer from ABS. Hopefully they will answer.  You mentioned 1/4" bolts.  I would discourage 1/4" with a vengeance and ABS also states that 3/8" is minimum.  1/4" does not allow for the idiot factor.  I have used 5/16 or 8mm at a pinch but I just had to replace 6 x 1/4" bolts on my hydraulic reservoir lid which had blown off and used 8mm Grade 8 equivalents.  Also onto a supplier of Titanium bolts.  Regards, Hugh




************************************************************************
************************************************************************
************************************************************************